FLOW PROFILER FCX-50
Make the temp. profile of Flow bath
Features
●High thermal performance, being smaller and lighter(6 points measurement, width 65mm)
●Bluetooth enables wireless data transfer to a PC
●The additional devices and TMR-1 software spread the width of measurement
(plus α 6 channels, plus α Observation monitor, plus α O2 concentration monitor, plus α Air velocity monitor)
●Install Battery level indicator
●Built-in Thermocouple disconnection checking function
●The provided cooling unit rapidly cools down a RCM-S main unit
Specifications
【Memory unit】
Items |
Specifications |
Model Name | FCX-50 |
Model Name | RCX-S |
Measuring Temp. Range | 0~500℃ * 1 |
Max Measuring Time | Approx. 10 hours * 1 * 2 |
Sampling Time (sec.) / Max. Storage Time | 0.05sec./4h50min, 0.1sec./10h40min,0.2sec./21h20min, 0.5sec./48h20min,1.0sec/96h40min, 2.0sec./193h20min,4.0sec/386h40min, 8.0sec./773h20min Arbitrary setup possible |
Temperature Accuracy | ±1℃ |
Measuning Points | 1-6 Points |
Heat Resistant Connector | Miniature Connector |
Input | Thermocouple JIS-K 110Ω max. 0.1 10m |
Power Supply | AAA battery Manganese batteries, Alkaline battery, Nickel-metal hydride |
Outer dimensions |
Memory unit :50 (W) x 170 (D) x 18 (H) mm (w/o Heat resistant case) Heat resistant case: 65 (W) x 245 (D) x 25 (H) mm |
Data Transmission Method | USB, Bluetooth |
Weight | Approx. 550g (Conveyor Attachment System are not included) |
*1 It differs from the heat resistant time of RCM-S main unit
*2 It is the experimental value by AAA batteries. The max. measuring time depends on battery capacity.
【Cooling Unit】
Model Name | RCF-3 |
Power Supply | AC100V~240 (Approx. 15W) 50/60Hz |
Fan | Square 120mm (2.9 m3 /min. Max.) 2 pcs. |
Input gas | Rc 1/8 screw connection Air 0.5Mpa following |
Outer Dimension | 350(W)×240(D)×160(H) (㎜) |
Weight | Approx. 5kg |
* The above specifications are subject to change without notice.