FLOW PROFILER FCX-50

Make the temp. profile of Flow bath

Flow Management Software
0.05sec Sampling Time

Features

●High thermal performance, being smaller and lighter(6 points measurement, width 65mm)

●Unnecessary Interface unit for the data transmission to a PC
●Bluetooth enables wireless data transfer to a PC
●The additional devices and TMR-1 software spread the width of measurement
   (plus α 6 channels, plus α Observation monitor, plus α O2 concentration monitor, plus α Air velocity monitor)

●Install Battery level indicator
●Built-in Thermocouple disconnection checking function
●The provided cooling unit rapidly cools down a RCM-S main unit


Specifications

【Memory unit】

Items

Specifications

Model Name FCX-50
Model Name RCX-S
Measuring Temp. Range 0~500℃ * 1
Max Measuring Time Approx. 10 hours * 1 * 2
Sampling Time (sec.) / Max. Storage Time 0.05sec./4h50min, 0.1sec./10h40min,0.2sec./21h20min, 0.5sec./48h20min,1.0sec/96h40min, 2.0sec./193h20min,4.0sec/386h40min, 8.0sec./773h20min Arbitrary setup possible
Temperature Accuracy ±1℃
Measuning Points 1-6 Points
Heat Resistant Connector Miniature Connector
Input Thermocouple JIS-K 110Ω max. 0.1 10m
Power Supply AAA battery Manganese batteries, Alkaline battery, Nickel-metal hydride
Outer dimensions

Memory unit :50 (W) x 170 (D) x 18 (H) mm

(w/o Heat resistant case)

Heat resistant case: 65 (W) x 245 (D) x 25 (H) mm

Data Transmission Method USB, Bluetooth
Weight Approx. 550g (Conveyor Attachment System are not included)

*1 It differs from the heat resistant time of RCM-S main unit

*2 It is the experimental value by AAA batteries. The max. measuring time depends on battery capacity.


【Cooling Unit】
Model Name RCF-3
Power Supply AC100V~240 (Approx. 15W) 50/60Hz
Fan Square 120mm (2.9 m3 /min. Max.) 2 pcs.
Input gas Rc 1/8 screw connection Air 0.5Mpa following
Outer Dimension 350(W)×240(D)×160(H) (㎜)
Weight Approx. 5kg

* The above specifications are subject to change without notice.